Storage Designed File System and Disk Layout from Storage to OS Wins,Unix (Lun,Raid,Volume,Group,FS,type,Cluster,Shared San)

** Myself


Example For Unix HP-UX with MC ServiceGuard Cluster,EVA storage with NFS


System
Device category
Raid type
Disk type
Disk Number or LUN Number
Volume Size or Vdisk Size
VDisk group name
Volume Group name
Logical Volume Group
Mount Point
Size
FS type
Shared NFS
Shared SAN For Cluster
PRD
On Local Disk
HW RAID 1
SAS
/dev/disk/disk34
142GB
No
vg00
lvol1
/stand
500MB
vxfs
-
-
lvol2
Primary swap/ dump
20GB
N/A
-
-
lvol3
/
2GB
vxfs
-
-
lvol4
/tmp
4GB
vxfs
-
-
lvol5
/home
800MB
vxfs
-
-
lvol6
/opt
15GB
vxfs
-
-
lvol7
/usr
20GB
vxfs
-
-
lvol8
/var
30GB
vxfs
-
-
lvswap1
Primary swap
. swap pri=2 0 0
20GB
N/A
-
-
lvusrsap
/usr/sap
20GB
vxfs
-
-
lvsapsw
/sapsoftware
30GB
vxfs
-
-
lvorabase
/oracle
5GB
vxfs
-
-
lvsapmntPRDexe
/sapmnt/PRD/exe
4GB
vxfs
-
-
On SAN
VRAID 1
FIBER
LUN 2
/dev/dsk/c8t0d2
/dev/dsk/c12t0d2
/dev/dsk/c10t0d2
/dev/dsk/c14t0d2
20GB
Fc_local_swap_PRD
vgswapPRD
lvswapPRD
Primary swap
. swap pri=1 0 0
20GB
N/A
-
-
On SAN
VRAD 1
FIBER
LUN 40
/dev/disk/disk20
4GB
Fc_saperp_prd_redo1
vgsapredoPRD
lvPRDoriglogA
/oracle/PRD/origlogA
1GB
vxfs
-
Share SAN
lvPRDoriglogB
/oracle/PRD/origlogB
1GB
vxfs
-
Share SAN
lvPRDmirrlogA
/oracle/PRD/mirrlogA
1GB
vxfs
-
Share SAN
lvPRDmirrlogB
/oracle/PRD/mirrlogB
1GB
vxfs
-
Share SAN
On SAN
VRAID 1
FIBER
LUN 41
/dev/disk/disk21
60GB
Fc_saperp_prd_arch1
vgsaparchPRD
lvPRDoraarch
/oracle/PRD/oraarch
60GB
vxfs
-
Share SAN
On SAN
VRAD 1
FIBER
LUN 42
/dev/disk/disk22
100GB
Fc_saperp_prd_sw1
vgswPRD
lvsapmntPRD
/export/sapmnt/PRD
10GB
vxfs
Share NFS
Share SAN
lvsaptransPRD
/export/usr/sap/trans
40GB
vxfs
Share NFS
Share SAN
lvenqASCS
/usr/sap/PRD/ASCS20
5GB
vxfs
-
Share SAN
lvenqSCS
/usr/sap/PRD/SCS21
5GB
vxfs
-
Share SAN
lvenqDVEBMGS
/usr/sap/PRD/DVEBMGS22
30GB
vxfs
-
Share SAN
On SAN
VRAD 1
FIBER
LUN 43
/dev/disk/disk23
150GB
Fc_saperp_prd_data1
vgsapdbPRD
lvorahomePRD
/oracle/PRD
20GB
vxfs
-
Share SAN
-
Share SAN
On SAN
VRAD 1
FIBER
LUN 44
/dev/disk/disk24
150GB
Fc_saperp_prd_data2
lvPRDsapdata1
/oracle/PRD/sapdata1
100GB
vxfs
-
Share SAN
lvPRDsapdata2
/oracle/PRD/sapdata2
100GB
vxfs
-
Share SAN
On SAN
VRAD 1
FIBER
LUN 45
/dev/disk/disk25
150GB
Fc_saperp_prd_data3
lvPRDsapdata3
/oracle/PRD/sapdata3
100GB
vxfs
-
Share SAN
lvPRDsapdata4
/oracle/PRD/sapdata4
100GB
vxfs
-
Share SAN



Example For Unix HP-UX with EVA storage with NFS
System
Device category
Raid type
Disk type
Disk Number or LUN Number
Volume Size or Vdisk Size
VDisk group name
Volume Group name
Logical Volume Group
Mount Point
Size
FS type
Shared NFS
PRD
On Local Disk
HW RAID 1
SAS
/dev/disk/disk3
142GB
No
vg00
lvol1
/stand
300MB
vxfs
-
lvol2
Primary swap/ dump
10GB
N/A
-
lvol3
/
2GB
vxfs
-
lvol4
/tmp
4GB
vxfs
-
lvol5
/home
800MB
vxfs
-
lvol6
/opt
10GB
vxfs
-
lvol7
/usr
15GB
vxfs
-
lvol8
/var
30GB
vxfs
-
lvswap1
Primary swap
20GB
N/A
-
lvusrsap
/usr/sap
20GB
vxfs
-
lvsapsw
/sapsoftware
30GB
vxfs
-
lvorabase
/oracle
5GB
vxfs
-
On SAN
VRAD 1
FIBER
LUN 50
/dev/disk/disk19
4GB
Fc_saperp_PRD_redo1
vgsapredoPRD
lvPRDoriglogA
/oracle/PRD/origlogA
1GB
vxfs
-
lvPRDoriglogB
/oracle/PRD/origlogB
1GB
vxfs
-
lvPRDmirrlogA
/oracle/PRD/mirrlogA
1GB
vxfs
-
lvPRDmirrlogB
/oracle/PRD/mirrlogB
1GB
vxfs
-
On SAN
VRAID 1
FIBER
LUN 51
/dev/disk/disk20
60GB
Fc_saperp_PRD_arch1
vgsaparchPRD
lvPRDoraarch
/oracle/PRD/oraarch
60GB
vxfs
-
On SAN
VRAID 1
FIBER
LUN 52
/dev/disk/disk21
100GB
Fc_saperp_PRD_sw1
vgswPRD
lvsapmntPRD
/sapmnt/PRD
10GB
vxfs
-
lvusrsapPRD
/usr/sap/PRD
30GB
vxfs
-
lvsaptransPRD
/usr/sap/trans
40GB
vxfs
Share NFS
lvorahomePRD
/oracle/PRD
20GB
vxfs
-
On SAN
VRAID 1
FIBER
LUN 53
/dev/disk/disk22
150GB
Fc_saperp_PRD_data1
vgsapdbPRD
lvPRDsapdata1
/oracle/PRD/sapdata1
100GB
vxfs
-
lvPRDsapdata2
/oracle/PRD/sapdata2
100GB
vxfs
-
On SAN
VRAID 1
FIBER
LUN 54
/dev/disk/disk23
150GB
Fc_saperp_PRD_data2
lvPRDsapdata3
/oracle/PRD/sapdata3
100GB
vxfs
-
-
On SAN
VRAID 1
FIBER
LUN 55
/dev/disk/disk24
150GB
Fc_saperp_PRD_data3
lvPRDsapdata4
/oracle/PRD/sapdata4
100GB
vxfs
-
-


Example For Windows with Smart Array (Local controller)
System
Device category
Raid type
Disk type
Disk Number or LUN Number
Volume Size or Vdisk Size
VDisk group name
Volume Group name
Drive
Size
FS type
PRD
On Local Disk
HW RAID 1
SAS
SAS Array A
80GB
No
Logical Drive1
C: (OS)
80 GB
ntfs
SAS Array A
190GB
No
Logical Drive2
D:(SAPKERNEL)
60 GB
ntfs
E:(SAPDATA)
100 GB
ntfs
F:(REDO)
2 GB
ntfs
G:(MIRRREDO)
2 GB
ntfs
H:(ARCH)
30 GB
ntfs

0 comments: